Noise Mitigation or Abatement It's a Constant Concern

Architectural solutions
Beyond the interior acoustics cited above under aircraft noise, there has been a steady trend to design quieter buildings with regard to sources within and without the structure itself.[citation needed] In the case of construction of new (or remodeled) apartments, condominiums, hospitals and hotels, many states and cities have stringent building codes with requirements of acoustical analysis, in order to protect building occupants. With regard to exterior noise, the codes usually require measurement of the exterior acoustic environment in order to determine the performance standard required for exterior building skin design. The architect can work with the acoustical scientist to arrive at the best cost-effective means of creating a quiet interior (normally 45 dBA). The most important elements of design of the building skin are usually: glazing (glass thickness, double pane design etc.), roof material, caulking standards, chimney baffles, exterior door design, mail slots, attic ventilation ports and mounting of through the wall air conditioners.
Regarding sound generated inside the building, there are two principal types of transmission. Firstly, airborne sound travels through walls or floor and ceiling assemblies and can emanate from either human activities in adjacent living spaces or from mechanical noise within the building systems. Human activities might include voice, amplified sound systems or animal noise. Mechanical systems are elevator systems, boilers, refrigeration or air conditioning systems, generators and trash compactors. Since many of these sounds are inherently loud, the principal design element is to require the wall or ceiling assembly to meet certain performance standards[7] (typically Sound transmission class of 50), which allows considerable attenuation of the sound level reaching occupants.
The second type of interior sound is called Impact Insulation Class (IIC) transmission. This effect arises not from airborne transmission, but rather from transmission of sound through the building itself. The most common perception of IIC noise is from footfall of occupants in living spaces above. This type of noise is more difficult to abate, but consideration must be given to isolating the floor assembly above or hanging the lower ceiling on resilient channel.
Both of the above transmission effects may emanate either from building occupants or from building mechanical systems such as elevators, plumbing systems or heating, ventilating and air conditioning units. In some cases it is merely necessary to specify the best available quieting technology in selecting such building hardware. In other cases shock mounting of systems to control vibration may be in order. In the case of plumbing systems there are specific protocols developed, especially for water supply lines, to create isolation clamping of pipes within building walls. In the case of central air systems, it is important to baffle any ducts that could transmit sound between different building areas.
Designing special purpose rooms has more exotic challenges, since these rooms may have requirements for unusual features such as concert performance, sound studio recording, lecture halls. In these cases reverberation and reflection must be analyzed in order to not only quiet the rooms but prevent echo effects from occurring. In these situations special sound baffles and sound absorptive lining materials may be specified to dampen unwanted effects.